Affected versions : CWA release 2402, 2403 or 2405
When launching a published Desktop users are presented with a grey window momentarily. This then closes but shows connected in connection center
Application launches will simply fail but the below error will be observed in the event logs
In the Application event logs you will see WFICA32 crash
Event log
-------------
Application Error 1000
Faulting application name: WFICA32.EXE, version: 24.2.0.187, time stamp: 0x660ee44a
Faulting module name: MSVCP140.dll, version: 14.30.30704.0, time stamp: 0x615a9224
Exception code: 0xc0000005
Fault offset: 0x00015883
Faulting process id: 0xc18
Faulting application start time: 0x01db498174697dd8
Faulting application path: C:\PROGRA~2\Citrix\ICACLI~1\WFICA32.EXE
Faulting module path: C:\windows\SYSTEM32\MSVCP140.dll
Report Id: e2a2efd0-30ee-40c3-9176-2872e495d9b5
Faulting package full name:
Faulting package-relative application ID:
Solution:
Either:
Update to the latest C++ redistributable:
https://aka.ms/vs/17/release/vc_redist.x86.exe
https://aka.ms/vs/17/release/vc_redist.x64.exe
Or
Upgrade CWA to a version that includes a compatible C++ version
2405 or above
https://www.citrix.com/downloads/workspace-app/windows/workspace-app-for-windows-latest.html
Incompatible Microsoft Visual C++redistributable version