Single Sign On not working when going through one FAS server - The RPC server is unavailable

Single Sign On not working when going through one FAS server - The RPC server is unavailable

book

Article ID: CTX461416

calendar_today

Updated On:

Description

Single Sign on through FAS is not working when going through specific FAS server.
if the affected FAS server is put into maintenance mode, all connections go through the remaining FAS server which works, confirming issue is related to one particular FAS Server.

When we check Certificate Authority, we get error The RPC server is unavailable. 0x800706ba (WIN32: 1722 RPC_S_SERVER_UNAVAILABLE).

Resolution

Make sure all windows updates are applied to the server machine. 

Once windows updates were applied, issue was resolved. 

Problem Cause

Issue seems related to - https://support.microsoft.com/en-us/topic/kb5004442-manage-changes-for-windows-dcom-server-security-feature-bypass-cve-2021-26414-f1400b52-c141-43d2-941e-37ed901c769c Data of issue occurring seems to match policy enforcement.