USB passthrough of mobile devices
Instructions
Following are the steps to setup USB Passthroug:
Samsung Android phones:
- Upgrade Receiver to 4.4 and VDA to 7.7
- HDX Policy must have the device rule set (Allow: VID=04E8 PID=6860 # Samsung Android Phone)
- Local Registry must also have the below Classes set to allow.
- ALLOW: class=0a # CDC-Data
- ALLOW: class=02 # Communications and CDC-Control
- The Group Policy “USB Devices List in Desktop Viewer” can be enabled or disabled.
Psion Windows Mobile Device.
- Upgrade Receiver to 4.4 and VDA to 7.7
- Set the receiver option “When a new device is connected… connect automatically” (if the local client does not have the drivers then the device will not show in the list of available connections.)
- HDX Policies and Local Registry settings did not affect this device.