How to Redirect Topaz Signature Pad – Model: T-LBK462-BSB-R to VDA

How to Redirect Topaz Signature Pad – Model: T-LBK462-BSB-R to VDA

book

Article ID: CTX212846

calendar_today

Updated On:

Description

This article explains how to map Topaz Signature Pad – Model: T-LBK462-BSB-R to VDA


Instructions

Citrix Policy on Controller

  1. Auto connect client COM ports – Enabled
  2. Client COM port redirection – Allowed
  3. Client USB device redirection – Allowed

VDA Registry 

Location: HKLM\Software\Citrix\GroupPolicy\Defaults\Deprecated
DWORD:  AllowComPortRedirection
Value: 1

Location: HKLM\Software\Citrix\GroupPolicy\Defaults\Deprecated
DWORD:  AutoConnectClientComPorts
Value: 1


-    Software installed on VDA – SigPlus
http://www.sigpluspro.com/sigplusbsb-index.html

-    Software installed on Client – SigPlus
http://www.sigpluspro.com/sigplusbsb-index.html 

-    No changed on the client registry 

Issue/Introduction

Map Topaz Signature Pad – Model: T-LBK462-BSB-R to VDA