USB devices prompting to connect on each session:

Environment
Caution! Using Registry Editor incorrectly can cause serious problems that might require you to reinstall your operating system. Citrix cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk. Be sure to back up the registry before you edit it.
Resolution
On the client machine
- Navigate to "C:\Program Files (x86)\Citrix\ICA Client\Configuration"
- Copy receiver.admx and CitrixBase.admx to "C:\Windows\PolicyDefinitions"
- Navigate to "C:\Program Files (x86)\Citrix\ICA Client\Configuration\en-US"
- Copy receiver.adml and CitrixBase.adml to "C:\Windows\PolicyDefinitions\en-US"
- Open Group Policy Editor and configure
- Set following policy:
- New USB Devices > Connect the USB device
- Existing USB Devices > Connect all available USB devices

Alternatively you can set the value via the registry:
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Policies\Citrix\ICA Client\USB
"NewDevices"="Always"
"ExistingDevices"="Always"
HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Citrix\ICA Client\USB
"NewDevices"="Always"
"ExistingDevices"="Always"
Problem Cause
Auto connect is not being set and end users are allowed to choose the devices to redirect