USB Devices prompting to connect on each session

USB Devices prompting to connect on each session

book

Article ID: CTX209540

calendar_today

Updated On:

Description

USB devices prompting to connect on each session:

User-added image

Environment

Caution! Using Registry Editor incorrectly can cause serious problems that might require you to reinstall your operating system. Citrix cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk. Be sure to back up the registry before you edit it.

Resolution

On the client machine

  1. Navigate to "C:\Program Files (x86)\Citrix\ICA Client\Configuration"
  2. Copy receiver.admx and CitrixBase.admx to "C:\Windows\PolicyDefinitions"
  3. Navigate to "C:\Program Files (x86)\Citrix\ICA Client\Configuration\en-US"
  4. Copy receiver.adml and CitrixBase.adml to "C:\Windows\PolicyDefinitions\en-US"
  5. Open Group Policy Editor and configure 
  6. Set following policy:
    • New USB Devices > Connect the USB device
    • Existing USB Devices > Connect all available USB devices


 
Alternatively you can set the value via the registry:
 
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Policies\Citrix\ICA Client\USB
"NewDevices"="Always"
"ExistingDevices"="Always"
HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Citrix\ICA Client\USB
"NewDevices"="Always"
"ExistingDevices"="Always"

Problem Cause

Auto connect is not being set and end users are allowed to choose the devices to redirect

Issue/Introduction

USB devices prompting to connect on each session. How do I make USB devices automatically connect to virtual sessions?