Hotfix ICAWS760WX64014 - For VDA Core Services 7.6 for Windows Desktop OS (64-bit) - English

Hotfix ICAWS760WX64014 - For VDA Core Services 7.6 for Windows Desktop OS (64-bit) - English

book

Article ID: CTX142157

calendar_today

Updated On:

Description

Filename: ICAWS760WX64014.msp
For: XenApp 7.6; XenDesktop 7.6 VDA Core Services for Windows Desktop OS (64-bit). For operating system requirements, see Citrix Product Documentation.
Replaces: ICAWS760WX64002
Date: April, 2015
Language supported: English (US), Japanese (JA), Simplified Chinese (SC)
Readme version: 1.00

Readme Revision History

VersionDateChange Description
1.00April, 2015Initial release

Important Note(s)

  • This release is based on Version 7.6 of the VDA Core Services for Windows Desktop (64-bit). It patches only systems where Version 7.6 of the VDA Core Services for Windows Desktop (64-bit) is installed. Any known issues in Version 7.6 of the product, except for the specific issues resolved in this limited release, still apply.
  • You can upgrade the VDA from a console session or from an RDP session. Upgrading from within an ICA session is not supported.
  • Caution! This release may require you to edit the registry. Using Registry Editor incorrectly can cause serious problems that may require you to reinstall your operating system. Citrix cannot guarantee that problems resulting from the incorrect use of Registry Editor can be solved. Use Registry Editor at your own risk.

Where to Find Documentation

This document describes the issue(s) resolved by this release and includes installation instructions. For additional product information, including supported operating systems and system requirements, see Citrix Product Documentation.

Known Issues in this Release

  1. In rare cases, reinstalling this MSP file can cause the Citrix Display Driver (Citrix Systems – WDDM) to get marked for deletion. In turn, this causes the reinstall to fail, leaving the VDA’s display resolution unusable. As a workaround, restart the VDA and then reinstall the MSP. After restarting the VDA, the driver is removed. Then, when you reinstall the MSP, the drivers are successfully reinstalled.

    [From ICAWS760WX64][#0528688]

New Fixes in This Release

  1. This fix reinstates the "Legacy printer names" policy, which was not previously available in Version 7.x of the product.

    [From ICAWS760WX64014][#LC1002]

Fixes from Replaced Hotfixes

  1. When the "Auto-Create Generic Universal Printer" policy setting is enabled, the Citrix Print Manager Service (CpSvc.exe) does not create the Citrix Universal Printer generic printer.

    [From ICAWS760WX64002][#LC1255]

Installing and Uninstalling this Release

Notes:

  • This release is packaged with Microsoft Windows Installer 3.0 as a .msp file. For more information about deploying .msp files, see Microsoft article 884016 or visit the Microsoft Web site and search on keyword msiexec.
  • This installer program complies with Microsoft User Account Control (UAC). If UAC is enabled, you must run the installer program in elevated mode; that is, with administrative privileges enabled. For more information about UAC, see Microsoft TechNet or visit the Microsoft Web site and search on keyword UAC.
  • To install this release successfully, computers must not have registry modification restrictions in place.
  • Slipstreaming - installations of the VDA for Windows Desktop OS base product packaged with one or more individual hotfixes - is not supported and might leave servers in an unstable state.
  • You must restart the server after the installation of this hotfix completes. However, if you are installing multiple hotfixes at the same time, there is no need to restart the server after the installation of each hotfix. It is sufficient to restart the server after the installation of the final hotfix completes.
  • If the need arises to restore the original settings and functionality provided by this release, you must uninstall the release before reinstalling it according to the installation instructions below.

To install this release:

  1. Copy the release package to an empty folder on the hard drive of the computer you want to update.
  2. Close all applications.
  3. Run the executable.
  4. Restart the computer.

To uninstall this release:

  1. From the Start menu, select Control Panel > Programs and Features.
  2. Highlight the release you want to uninstall and click Uninstall.
  3. Follow the directions on-screen.

Files Updated (All Dates/Times UTC)

File Name

Date

Time

Size

CPatch.exe
03/18/2015
08:33
338,288
CpSvc.exe
03/18/2015
08:33
923,928
CpSvc64.exe
03/18/2015
08:33
1,159,960
CtxHfLoader.dll
03/18/2015
08:33
395,648
ctxregasm.exe
03/18/2015
08:33
26,576
msi50ca.dll
03/18/2015
08:33
633,136
SDKv06_RunTime_Xml
03/18/2015
08:33
334
Error.idt (en)
03/18/2015
08:33
35,673
CPatchUI.dll (x32\de)
03/18/2015
08:33
14,200
CPatchUI.dll (x32\en)
03/18/2015
08:33
13,688
CPatchUI.dll (x32\es)
03/18/2015
08:33
14,712
CPatchUI.dll (x32\fr)
03/18/2015
08:33
14,200
CPatchUI.dll (x32\ja)
03/18/2015
08:33
12,152
CPatchUI.dll (x32\zh-cn)
03/18/2015
08:33
11,640
 
File Name

MD5 Checksum

ICAWS760WX64014.msp
EB50F410D20933EBA091A792514A5C54
CPatch.exe
B552C4ADFC4EBDBC198EB2620F282709
CpSvc.exe
BDA8EE42D607C316AE2C99455B85B41F
CpSvc64.exe
531C345C04A7803261222A4550E8CFB5
CtxHfLoader.dll
3342F05F9EE6F862172AC3150F804149
ctxregasm.exe
07207F40A7704D248E14594672B72CC4
msi50ca.dll
BB76F5052E66F03DBDF6B43399111186
SDKv06_RunTime_Xml
02C86CD1A05CE7F5BF41291C7AA6B595
Error.idt (en)
8370B4898257DD82C2D81D3EF1BE893E
CPatchUI.dll (x32\de)
E4F3BD678E21553FD6B3BB48F2BDB297
CPatchUI.dll (x32\en)
1D5BC99B2A180E49381C086804B70F69
CPatchUI.dll (x32\es)
EAFEEF8AAA7BEBE89139D1AA0150A5B5
CPatchUI.dll (x32\fr)
E2AC887A998BBC67CC3BEC4A7705EECB
CPatchUI.dll (x32\ja)
A86BB78D0F01E8A8D82868E7B3FFF9E5
CPatchUI.dll (x32\zh-cn)
4D5B49F6F74FAF217C543D21DBCD3F91