Device Names Assigned to /var and /flash Partitions According to BIOS Version Installed on a NetScaler MPX Appliance

Device Names Assigned to /var and /flash Partitions According to BIOS Version Installed on a NetScaler MPX Appliance

book

Article ID: CTX124609

calendar_today

Updated On:

Description

This article contains information about the changes to the Basic Input Output System (BIOS) version in the NetScaler MPX appliances shipped from Citrix and the names for the /flash and /var directories used with the earlier and latest versions of BIOS on the appliances.

The following table lists the names assigned to the /var and /flash partitions according to the BIOS version installed on the various models of the NetScaler MPX appliances:

NetScaler MPX Appliance ModelBIOS VersionRelease DateHDD Partition
(/var)
Flash / SSD
Partition
(/flash)
26100/26160/26200-100G8.2q10/16/2017/dev/ar0s1e/dev/ar0s1a
26200T-100G8.2q10/16/2017/dev/ar0s1e/dev/ar0s1a
26160T-100G8.2q10/16/2017/dev/ar0s1e/dev/ar0s1a
26100T-100G8.2q10/16/2017/dev/ar0s1e/dev/ar0s1a
55002.0a04/30/2009/dev/ad6s1e/dev/ad4s1a
2.0d10/20/2009/dev/ad0s1e/dev/ad4s1a
55502.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
55602.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
55702.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
55802.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
56502.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
59013.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
59053.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
59103.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
75002.0a04/30/2009/dev/ad6s1e/dev/ad4s1a
2.0d10/20/2009/dev/ad0s1e/dev/ad4s1a
2.1a06/20/2011/dev/ad0s1e/dev/ad4s1a
76002.1a06/20/2011/dev/ad0s1e/dev/ad4s1a
80002.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
82002.1a08/13/2012/dev/ad4s1e/dev/ad4s1a
2.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
84002.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
86002.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
88002.1d09/06/2012/dev/ad4s1e/dev/ad4s1a
89053.2e3/31/2017/dev/ad0s1e   /dev/ad0s1a
89103.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
89203.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
89303.2e3/31/2017/dev/ad0s1e/dev/ad0s1a
95002.0a04/30/2009/dev/ad6s1e/dev/ad4s1a
2.0d10/20/2009/dev/ad0s1e/dev/ad4s1a
2.1a06/20/2011/dev/ad0s1e/dev/ad4s1a
96002.1a06/20/2011/dev/ad0s1e/dev/ad4s1a
97004.0a07/16/2009/dev/ad6s1e/dev/ad4s1a
 
9700 – 10 GB
4.0c10/05/2009/dev/ad0s1e/dev/ad4s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.1c10/05/2009/dev/ad0s1e/dev/ad4s1a
105004.0a07/16/2009/dev/ad6s1e/dev/ad4s1a
 
10500 – 10 GB
4.0c10/05/2009/dev/ad0s1e/dev/ad4s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.1c10/05/2009/dev/ad0s1e/dev/ad4s1a
115003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
125004.0a07/16/2009/dev/ad6s1e/dev/ad4s1a
 
12500 – 10 GB
4.0c10/05/2009/dev/ad0s1e/dev/ad4s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.1c10/05/2009/dev/ad0s1e/dev/ad4s1a
135003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
145003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
150003.0a02/20/2008/dev/ad4s1e/dev/ad0s1a
155003.1c10/21/2009/dev/ad0s1e/dev/ad2s1a
4.0a07/16/2009/dev/ad6s1e/dev/ad4s1a
15500 (10 GB)4.0c10/05/2009/dev/ad0s1e/dev/ad4s1a
3.1c10/05/2009/dev/ad0s1e/dev/ad4s1a
165003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
17000 (28 GB)3.0a02/20/2008/dev/ad4s1e/dev/ad0s1a
 
17000 (40 GB)
3.1c10/21/2009/dev/ad0s1e/dev/ad2s1a
2.0a02/20/2008/dev/ad4s1e/dev/ad0s1a
2.0b09/24/2009/dev/ad0s1e/dev/ad2s1a
175002.1c10/21/2009/dev/ad0s1e/dev/ad2s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.2a05/03/2011/dev/ad5s1e/dev/ad4s1a
175502.0e04/23/2010/dev/ad5s1e/dev/ad4s1a
3.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
185003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
 
19500
2.0e04/23/2010/dev/ad5s1e/dev/ad4s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.2a05/03/2011/dev/ad5s1e/dev/ad4s1a
195503.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
205003.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
205503.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
215002.0e04/23/2010/dev/ad5s1e/dev/ad4s1a
2.0c02/24/2010/dev/ad5s1e/dev/ad4s1a
3.2a05/03/2011/dev/ad5s1e/dev/ad4s1a
215503.2a05/03/2011/dev/ad8s1e/dev/ad4s1a
220402.0n04/18/2013/dev/ad6s1e/dev/da0s1a
220602.0n04/18/2013/dev/ad6s1e/dev/da0s1a
220802.0n04/18/2013/dev/ad6s1e/dev/da0s1a
221002.0n04/18/2013/dev/ad6s1e/dev/da0s1a
221202.0n04/18/2013/dev/ad6s1e/dev/da0s1a
17550 SDX4.0b08/05/2011/dev/sdb/dev/sda4
241002.0e03/8/2013/dev/ad6s1e/dev/ad4s1a
241502.0e03/8/2013/dev/ad0s1e/dev/ad4s1a
25100T4.0b12/8/2014/dev/ad4s1e/dev/ad4s1a
25160T4.0b12/8/2014/dev/ad4s1e/dev/ad4s1a
140205.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
140305.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
140405.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
140605.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
140805.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
141005.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
145005.0c08/07/2014/dev/ar0s1e/dev/ad4s1a
25100-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
25160-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
14020-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
14040-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
14060-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
14080-40G5.0c08/07/2014/dev/ar0s1e/dev/ar0s1a
14030-FIPS5.0c08/07/2014/dev/ar0s1edev/ar0s1a
14060-FIPS5.0c08/07/2014/dev/ar0s1edev/ar0s1a
14080-FIPS5.0c08/07/2014/dev/ar0s1edev/ar0s1a
14040-40S5.0n08/07/2014/dev/ar0s1edev/ar0s1a
14060-40S5.0n08/07/2014/dev/ar0s1edev/ar0s1a
14080-40S5.0n08/07/2014/dev/ar0s1edev/ar0s1a
14100-40S5.0n08/07/2014/dev/ar0s1edev/ar0s1a
115153.4a /dev/ad8s1edev/ad4s1a
115203.4a /dev/ad8s1edev/ad4s1a
115303.4a /dev/ad8s1edev/ad4s1a
115403.4a /dev/ad8s1edev/ad4s1a
115423.4a /dev/ad8s1edev/ad4s1a
80052.1d7/3/2012/dev/ad4sledev/ad4sla
80102.1d7/3/2012/dev/ad4sledev/ad4sla
80152.1d7/3/2012/dev/ad4sledev/ad4sla

Additional Resources

To verify the BIOS version installed on the NetScaler MPX appliance run the following command from the shell prompt of the appliance:
root@ns# grep platform /var/nslog/dmesg.boot

platform: smbios_read failed
platform: bios version 3.1c dated 10/05/2009 found at 0xf19f5036
platform: Manufacturer Citrix Inc.
platform: Product NSMPX-10500
platform: NSMPX-10500 2*10G+8*1G Ports by Citrix Inc. (BIOS 3.1c by 10/05/2009), serial DDFP61UZ89
platform: NSMPX-10500 8*CPU+2*E1K+8*E1K+2*IX+8*CVM 1620 760100 (14), manufactured at 11/10/2009
platform: serial DDFP61UZ89
platform: CPU 2829MHz, Host 65c08086, ID=760100/760100
platform: sysid 760100 - NSMPX-10500 8*CPU+2*E1K+8*E1K+2*IX+8*CVM 1620

For more information about the file system and related information, refer to the following Knowledge Center articles:

CTX109006 – How to Recover the Password for a NetScaler Appliance

CTX121853 – Device Names Assigned to Hard Disk in Various Models of the Citrix NetScaler Appliance

CTX122687 – How to Mount the Flash Drive by Using an Appropriate Device Name on a NetScaler Appliance

Issue/Introduction

This article contains information about the recent BIOS changes on the various NetScaler MPX appliance models shipped from Citrix. The device name of the /flash and /var partitions change according to the BIOS version on the appliance.