CWA for Windows 2607 - Installation Fails with Error 1603 Due to Missing NetworkProvider\Order Registry Key

book

Article ID: CTX697148

calendar_today

Updated On:

Description

During the installation of Citrix Workspace App 2607, the setup failed and rolled back.

The installation log contained entries similar to the following:

AddOrRemoveSsonProvOrder: Could not open key for access

AddOrRemoveSsonProvOrder has failed
CusRemoveSsonFrmProvOrder has failed
CustomAction CtxSsonRemoveProvider
FBBB1C11_117D_XXX returned actual error code 1603

The errors occurred during the execution of Citrix Workspace App custom actions responsible for managing the Citrix Single Sign-On (SSON) network provider configuration.

Further investigation identified that the following registry path was missing:

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\NetworkProvider\Order

Cause

The registry key is a standard Windows networking configuration location used to define the order in which network providers are loaded and accessed by the operating system.

Citrix Workspace App SSON functionality integrates with the Windows network provider stack. During installation, the installer attempts to read and modify values under the NetworkProvider\Order registry key to register or update the Citrix Single Sign-On provider.

If this registry key is missing, corrupted, or inaccessible, the installer cannot complete the required SSON provider configuration tasks. As a result, the custom action fails and the MSI installation terminates with Error 1603.

Resolution

Launch Registry Editor (regedit.exe) with administrative privileges.

Navigate to: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\NetworkProvider

Manually recreate: HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\NetworkProvider\

Name:Order 
Type:String
Data: RDPNP,LanmanWorkstation,webclient (this is the default value)

Issue/Introduction

A customer was unable to install Citrix Workspace App (CWA) 2607. Review of the installation log revealed failures related to the Single Sign-On (SSON) provider registration process, resulting in a fatal MSI error 1603. Investigation determined that the registry key HKLM\SYSTEM\CurrentControlSet\Control\NetworkProvider\Order was missing from the operating system. After recreating the missing registry key, the installation completed successfully.