Citrix Workspace app does not start on eLux 7.2607 after upgrade — StoreFront connection returns an empty application list (missing Self-service component)

book

Article ID: CTX697072

calendar_today

Updated On:

Description

Applies to: eLux 7.2607 (and any image using Citrix Workspace app for Linux 26.04 or later), Scout-managed, StoreFront connection configured as an eLux application of Type 17. Reproduced with both on-premises and cloud stores.

Symptoms:

  • The Citrix connection does not start at boot despite Autostart=true.

  • Starting it manually produces no window, no logon prompt, and no error message.

  • The configuration appears correct: the store is present and reachable, and StoreFront, DNS and certificates are all healthy.

  • Changing between CWA 26.04 builds makes no difference.

In /tmp/eluxd.log, the store is added successfully but no resources are returned:

Plain text

storebrowse --addstore https:///Citrix/       cmdStatus=0
storebrowse -ibest --enumerate https:///citrix//discovery
receiveResources (): no cache file found ... skipped
receiveResources (): done, found 0 resources
ApplicationManager::startAllAutostartApplications: Could not start application ''

The enumerate step consistently takes approximately 11.5 seconds — roughly 1.5 seconds of start-up plus a 10-second timeout.

The cause is only visible with Citrix enhanced logging enabled. storebrowse does not write to ICAClient.log; it writes its own log to /var/log/ica/dslog, which records:

Plain text

Proceeding with Selfservice IPC offload
Checking lockpath /home/elux/.ICAClient/.tmp/.selfserv.lock
Unable to start selfservice daemon
Error message after completing worker Code: 0.

To enable enhanced logging, set the following in /setup/ica/AuthManConfig.xml:

XML

TracingEnabledtrue
LoggingModenormal
ExtendedLoggingEnabledtrue

Cause

Citrix Workspace app for Linux 26.04 changed how the published application list is produced. storebrowse --enumerate no longer performs the enumeration itself; it hands the task to the Self-service helper daemon over IPC ("Selfservice IPC offload"). This applies to both on-premises and cloud stores.

The Self-service component (ica_selfservice) is an optional feature package within the Citrix Workspace app for Linux EPM and is not selected by default. When it is absent, storebrowse cannot start the daemon, waits ten seconds, and then exits with return code 0 and zero resources. Because the command reports success, no error is raised to eLux — the connection simply has nothing to display or launch.

CWA 26.01 and earlier performed the enumeration directly and did not require this component. An image that omits Self-service therefore works before the upgrade and fails afterwards, with no change to the eLux or StoreFront configuration. Adding the store uses a different code path that does not involve the daemon, which is why that step still succeeds and the configuration appears valid.

Resolution

Add the Self-service component to the image:

  1. In ELIAS, open the Citrix Workspace app for Linux package (version 26.04 or later).

  2. Select Self-service — listed directly below "Utilities and tools".

  3. Save the image and update the affected devices, then reboot.

No other change is required. The Citrix extensions package and the "Support of web based UI dialogs" option do not need to be modified, and no CWA version change is necessary.

Verification: after reboot, the StoreFront connection starts and presents the published applications. In /tmp/eluxd.log, the enumerate step should complete in well under ten seconds and report a non-zero resource count.

Alternative (only where the Self-service component cannot be added): set true in /setup/ica/AuthManConfig.xml to prevent storebrowse delegating to the daemon. This has not been validated and should be treated as a workaround rather than a fix.

Preventive guidance: when moving an image to CWA 26.04 or later, confirm that Self-service is selected. Any upgrade report of "Citrix does not start" or an empty application list should be checked against this first.

Issue/Introduction

After upgrading eLux from 7.2605 to 7.2607, a StoreFront connection (Type 17) fails to start. Nothing appears on screen on either autostart or manual start, and no error is displayed. The store is added successfully, but the application list returned is empty. This occurs because CWA 26.04 and later require the Self-service component to enumerate published resources, and that component is not selected in the image.