NetScaler -13.1 56.18 - Non-recoverable : potential damage: system hardware in jeopardy or damaged
book
Article ID: CTX692891
calendar_today
Updated On:
Description
The Citrix NetScaler SDX 16000 appliance may exhibit the following symptoms:
The appliance reports critical voltage errors in the ns.log and system message logs, indicating potential hardware damage.
Specific Log Entries: The following log entries, or similar variations, are observed:
Mar 9 19:45:54 <local0.crit> hostname svm_event: xxx.xxx.xxx.xxx : EVENT VOLTAGEERROR : xxx.xxx.xxx.xxx:HealthMonitoring:Vcpu1VCCIN - Vcpu1VCCIN : Non-recoverable : (potential damage: system hardware in jeopardy or damaged) Mar 10 21:41:29 <local0.crit> hostname svm_event: xxx.xxx.xxx.xxx : EVENT VOLTAGEERROR : xxx.xxx.xxx.xxx:HealthMonitoring:Vcpu1VCCIN - Vcpu1VCCIN : Non-recoverable : (potential damage: system hardware in jeopardy or damaged) Mar 11 02:35:05 <local0.crit> hostname svm_event:xxx.xxx.xxx.xxx : EVENT VOLTAGEERROR : 169.254.0.1:HealthMonitoring:Vcpu1VCCIN - Vcpu1VCCIN : Non-recoverable : (potential damage: system hardware in jeopardy or damaged) Mar 11 05:36:12 <local0.crit> hostname svm_event: xxx.xxx.xxx.xxx : EVENT VOLTAGEERROR : 169.254.0.1:HealthMonitoring:Vcpu2VDDQEFGH - Vcpu2VDDQEFGH : Non-recoverable : (potential damage: system hardware in jeopardy or damaged)
IPMI Log Information: IPMI tool logs show the following device information:
Device ID : 32 Device Revision : 1 Firmware Revision : 2.13 -------> LOM version IPMI Version : 2.0 Manufacturer ID : 10876 Manufacturer Name : Supermicro Product ID : 6983 (0x1b47) Product Name : Unknown (0x1B47) Device Available : yes Provides Device SDRs : no Additional Device Support : Sensor Device SDR Repository Device SEL Device FRU Inventory Device IPMB Event Receiver IPMB Event Generator Chassis Device Aux Firmware Rev Info : 0x12 0x01 0x00 0x00
Stable Voltage Readings: Despite the reported voltage errors, sensor readings from the IPMI tool indicate that the actual voltage supplied to the appliance is within acceptable ranges.
Follow below troubleshooting steps to resolve this:
1. Firmware Upgrade: The primary solution is to upgrade the LOM firmware to version 3.11. This upgrade has been specifically designed to address the reported issue. Please follow your organization's standard procedures for firmware updates.
2. Power Cycle: If the firmware upgrade does not resolve the issue, a power cycle may be necessary. Carefully disconnect the power cable from the affected device. Wait for a minimum of five (5) minutes. Reconnect the power cable.
3. Contact Technical Support: If the issue persists after both the firmware upgrade and power cycle, it indicates a potential hardware failure. Please contact technical support for further diagnosis and to initiate the RMA process.