Citrix ADC MPX/SDX Fortville NIC Err-Disabled when LLDP Is enabled on Peer Switch/Router
book
Article ID: CTX461349
calendar_today
Updated On:
Description
If Citrix ADC is connected to a switch/router via Fortville NIC (For example 10G port on MPX 8900), interface will show UP for a moment then go to Err-Disabled state. Running "show interface" command on ADC, you can find ADC Fortville NIC is in Err-Disabled State, along with TX Stall and Hang counts. Issue can be reproduced even if the NIC is bound to a channel.
Enable/Disable the interface can't recover, but reboot can bring UP state back. However, issue will happen again.
Environment
Citrix is not responsible for and does not endorse or accept any responsibility for the contents or your use of these third party Web sites. Citrix is providing these links to you only as a convenience, and the inclusion of any link does not imply endorsement by Citrix of the linked Web site. It is your responsibility to take precautions to ensure that whatever Web site you use is free of viruses or other harmful items.
Resolution
Current Workaround: 1. Disable LLDP on peer Switch/Router. 2. Reboot ADC to recover the error state.
Upcoming Solution: Citrix ADC Engineering team is working on qualifying newer versions of Fortville firmware from Intel, an ADC firmware upgrade will include the fix in the future and this article will be updated.
Problem Cause
This is caused by a NIC firmware compatibility issue with LLDP. Triggers are:
LLDP is enabled on peer router/switch, not matter LLDP configuration on ADC.
Note: Possibility is not 100% when peer sending LLDP messages. There're some unknown triggers under Intel investigation.
Issue/Introduction
There is a known compatibility issue on Fortville NICs with LLDP, NIC goes into Err-disabled state. Disable LLDP on Switch/Router that cabling with ADC can help workaround this issue.