Citrix Provisioning - Unable to add a new server to the Farm

Citrix Provisioning - Unable to add a new server to the Farm

book

Article ID: CTX692736

calendar_today

Updated On:

Description

Configuration Wizard shows warnings when admin tries to add a new PVS Server to the Farm.

Error displayed: Errors have occured during the configuration process 

ConfigurationWizard.log located in C:\ProgramData\Citrix\Provisioning Services on the PVS Server shows the errors:

ERROR:CommunicationException: Could not connect to net.tcp://EXISTINGPVSSERVERNAME:54322/pvs/mapi/keyexchangecommandset

 

Resolution

Allow communication between all PVS Servers in the farm on port 54322 on the firewall.


Problem Cause

Firewall blocking communciation between PVS Servers on port 54322.