ADM collector metric services port 5563 is down on VPXs
book
Article ID: CTX574664
calendar_today
Updated On:
Description
Traffic Management > Load Balancing > Service
ADM collector metric services (port 5563) <adm_metric_collector_svc_ADM_IP> is down on the VPX

Resolution
- Login to the NS GUI from browser
- Enabled Appflow parameter for Time series Data over NSIP from Global Appflow Setting.
- Run Below command from CLI to configure this feature, which brings the collector service as UP.
set appflow param -TimeseriesOverNSIP ENABLED

Problem Cause
Time series collector service(adm_metric_collector_svc_ADM_IP) showing DOWN as
No SNIP configured for the in ADM server subnet
Error "No MIP/SNIP available to send the monitor probe"
Only NSIP is in ADM server subnet and reachable soi we are forcing the ADC to send the probe for ADM via NSIP.