Unable to Export the new configuration from the SD-WAN Center to the Change Management Inbox

Unable to Export the new configuration from the SD-WAN Center to the Change Management Inbox

book

Article ID: CTX269133

calendar_today

Updated On:

Description

Unable to Export the new configuration from the SD-WAN Center to the Change Management Inbox of MCN and displayed with following error message:


UnderĀ SDWANCENTER_management.log , the following error message can be seen as shown in the below log snippet:

Log Snippet:
==========


00000:097:509:112 INFO write_fuse_upload_config@appliance_monitor.cpp:1596 Request to upload config /home/talariuser/data/workspaces/1/configs/<Configfile>/<Configfilename.zip> to XX.XX.XX.XX by admin.

00000:097:523:099 ERR upload_config_to_appliance@appliance_monitor.cpp:1315 The file <Configfilename.zip> exists.: reason=A put operation must already be in progress...

Resolution

Import the problematic configuration file to SDWAN Centre > Save the configuration file with a different name and proceed with an export.

Problem Cause

The earlier configuration export was not terminated properly and it has become a Stale configuration on the SDWANCentre. Thus, configuration export using the same file name was not succeeded.