Reverse Imaging with UEFI targets fail with error : "failed to write disk" while doing the reverse image from vdisk to volume
book
Article ID: CTX269065
calendar_today
Updated On:
Description
Description:
Unable to create a new vDisk after performing reverse imaging to upgrade VM Ware Tools

Resolution
Solution:
Refer : https://docs.citrix.com/en-us/provisioning/7-15/upgrade/upgrade-vdisks/upgrade-vdisks-reimage.html
Run the P2PVS imaging wizard
- Check for ghost NICs on the target devices and confirm all ghost NICs are removed.
- Check for SATA controllers and confirm that No SATA controllers are in use on target device.
NOTE:
1. Check if disk was accessible
2. If the disk is not accessible , check after restarting the target
3. Removed and re-add the disk and confirm that disk is accessible and volumes are not created
4. Start the reverse imaging
Was this article helpful?