"Table chb_Config.PowerTimeSchemes object definition does not match the expected reference schema" Warning In Test Site Report On Upgrading From 1811 to 1903
book
Article ID: CTX256891
calendar_today
Updated On:
Description
After successfully the XenApp/XenDesktop site from v1811 to v1903, everything appears to be functioning normally. However, in Citrix Studio, under common tasks, the "Test Site" throws the following warning:
Table chb_Config.PowerTimeSchemes object definition does not match the expected reference schema.
Restore the database xxxx to the most recent backup.
On comparing the SQLSchemaInfo dump of the site database from Customer's upgraded site with the SQLSchemaInfo dump from a new 1903 site in lab it was found that there was a difference in value of CK_PowerTimeSchemes_PeakHalfHours in chb_config. PowerTimeSchemes table as highlighted below which resulted in the warning.
Resolution
A private under LD1616 was created to address the issue for 1903 but implementing the private would prompt for Database upgrade. This issue has been fixed in Virtual and and Desktops1909 version.
Problem Cause
Known issue in the product.
Issue/Introduction
"Table chb_Config.PowerTimeSchemes object definition does not match the expected reference schema" Warning In Test Site Report On Upgrading From 1811 to 1903
Was this article helpful?
thumb_up
Yes
thumb_down
No