Provisioning Services | Unable to Reverse Image A vDisk Using P2PVS, Getting "The Destination Disk Is Too Small"

Provisioning Services | Unable to Reverse Image A vDisk Using P2PVS, Getting "The Destination Disk Is Too Small"

book

Article ID: CTX238884

calendar_today

Updated On:

Description

Reverse imaging error - Unable to reverse image a vDisk using P2PVS getting "The destination Disk is too small"

Resolution

  • Remove the write cache disk.
  • Re-run the P2PVS so that there will be only one physical disk attached to the target device.


Problem Cause

  • In this case it is selecting write cache as target drive instead of the other local hard drive that was attached and throwing this error.
  • When we perform reverse imaging we need to attach a new local disk to the Target Device.
  • In case we have any additional disk even the write cache disk, P2PVS will considered that as the target disk.
  • As per the requirement the target disk shall either be of the same size or a little larger than the vDisk size. Write cache being a smaller disk when got selected as target disk, it throws this error.

Additional Information

https://support.citrix.com/article/CTX202159