Remote PC 7.15 - ICA Session getting Disconnected when Ctrl + Alt + Del Keys are keyed on Physical Machine

Remote PC 7.15 - ICA Session getting Disconnected when Ctrl + Alt + Del Keys are keyed on Physical Machine

book

Article ID: CTX236419

calendar_today

Updated On:

Description

ICA Session getting Disconnected when Ctrl + Alt + Del Keys are keyed on Physical Remote PC Machine.

Resolution

Check if the following registry keys are present in the Following location


1. HKLM\SOFTWARE\Citrix\PortICA\

DWORD - ForceEnableRemotePC value 1
DWORD - PorticaV2 value 1

Registry Key

2. HKLM\SOFTWARE\Citrix\PortICA\RemotePC
DWORD - RpcaMode Value 1
DWORD - RpcaTimeout Value 30
DWORD - SasNotification 1

Registry Key
Create the Keys if they are missing and reboot the Remote PC.

Now users will  getting the Option to allow or Don't Allow user when  Ctrl + Alt + Del Keys are keyed on Physical  Remote PC Machine.


Registry Key


 

Problem Cause

Registry Keys Configured under HKLM\SOFTWARE\Citrix\PortICA are missing.

Issue/Introduction

ICA Session getting Disconnected when Ctrl + Alt + Del Keys are keyed on Physical Machine

Additional Information

https://docs.citrix.com/en-us/xenapp-and-xendesktop/7-15-ltsr/install-configure/remote-pc-access.html