book
Article ID: CTX230590
calendar_today
Updated On:
Description
PVS - 7.1 upgrade to 7.8 - The wrong database version is being used. Found version: xx Expected version number: xx
Resolution
Choose the radio button: "Farm is already configured" while running configuration wizard after PVS server upgrade.

Problem Cause
An example: After upgrade as per: https://docs.citrix.com/en-us/provisioning/7-8/upgrade/pvs-upgrade-servers.html - In the configuration wizard, if we use "
Join to an existing farm" instead of "
Farm is already configured" then due to this
we will not be asked for a DB upgrade and the software will be upgraded to 7.8 but the DB version will still be the same - '11' (however, it should be 40).
The same will be for all other PVS versions too.
FYI PVS software versions and their DB versions:
PVS 7.12 - 70
PVS 7.11 - 60
PVS 7.9 - 50
PVS 7.8 - 40
Issue/Introduction
PVS - 7.1 upgrade to 7.8 - The wrong database version is being used. Found version: xx Expected version number: xx