The wrong database version is being used. Found version: xx Expected version number: xx

The wrong database version is being used. Found version: xx Expected version number: xx

book

Article ID: CTX230590

calendar_today

Updated On:

Description

PVS - 7.1 upgrade to 7.8 - The wrong database version is being used. Found version: xx Expected version number: xx

User-added image
User-added image

Resolution

Choose the radio button: "Farm is already configured" while running configuration wizard after PVS server upgrade.

User-added image

Problem Cause

An example: After upgrade as per: https://docs.citrix.com/en-us/provisioning/7-8/upgrade/pvs-upgrade-servers.html - In the configuration wizard, if we use "Join to an existing farm" instead of "Farm is already configured" then due to this we will not be asked for a DB upgrade and the software will be upgraded to 7.8 but the DB version will still be the same - '11' (however, it should be 40).

The same will be for all other PVS versions too.

FYI PVS software versions and their DB versions:
PVS 7.12 - 70

PVS 7.11 - 60

PVS 7.9 - 50

PVS 7.8 - 40

Issue/Introduction

PVS - 7.1 upgrade to 7.8 - The wrong database version is being used. Found version: xx Expected version number: xx

Additional Information

https://docs.citrix.com/en-us/provisioning/7-8/upgrade/pvs-upgrade-servers.html