Error 0x7B INACCESSIBLE_BOOT_DEVICE after installing PVS server on a Cisco UCS Server

Error 0x7B INACCESSIBLE_BOOT_DEVICE after installing PVS server on a Cisco UCS Server

book

Article ID: CTX229180

calendar_today

Updated On:

Description

After installing PVS Server software, or upgrading from a previous version, the first time the server reboots it will not be able to boot successfully anyomre.
The server might present a Blue Screen with Error Code 0x7B INACCESSIBLE_BOOT_DEVICE
 

Resolution

The following workaround can be used to overcome the issue.
  1. Before installing the PVS Software, uninstall the EMC Powerpath software from the server. Do not reboot after uninstallation
  2. Install the PVS Server Software. Do not reboot after installation
  3. Re-Install the EMC Powerpath software
  4. Reboot the server