Users can access the enumerate but is receiving error ""The connection to windows 7 dekstop failed with status (There is no citrix xenapp server configured on the specified IP address) " when trying to launch the application.
We can see that the SF is sending out the XA server IP instead of passing out the STA ticket.
GET /Citrix/CIP-XenApp7Web/Resources/LaunchIca/WGVuQXBwNy5BbGwgdXNlcnMgaW4gWGVuQXBwN19Vc2VycyAkUzEtMg--.ica?
Response
===========================
HTTP/1.1 200 OK
Cache-Control: private, max-age=0, s-maxage=0
Content-Type: application/x-ica; charset=utf-8
Expires: Sun, 24 Jul 2016 23:30:37 GMT
Last-Modified: Sun, 24 Jul 2016 23:30:37 GMT
Server: Microsoft-IIS/8.5
X-Powered-By: ASP.NET
X-Citrix-Application: Receiver for Web
Date: Sun, 24 Jul 2016 23:30:37 GMT
Content-Length: 1382
[Encoding]
InputEncoding=UTF8
[WFClient]
ProxyFavorIEConnectionSetting=Yes
ProxyTimeout=30000
ProxyType=Auto
ProxyUseFQDN=Off
RemoveICAFile=yes
TransportReconnectEnabled=On
Version=2
VirtualCOMPortEmulation=On
[ApplicationServers]
All users in XenApp7_Users $S1-2=
[All users in XenApp7_Users $S1-2]
Address=192.168.104.121:1494
AutologonAllowed=ON
BrowserProtocol=HTTPonTCP
Resolution
==================
Please verify the store settings on the Storefront
- Ensure that there is no Delivery controller defined on the Direct HDX connection
-