Volume set to 100% in pooled machines
book
Article ID: CTX208055
calendar_today
Updated On:
Description
In Pooled machines the Volume is always set to 100%. Even if the volume level is changed on the master image the change is not seen in the machines created using this Master VM
Resolution
- Import the Master Image as a physical machine to Studio (Create a catalog)
- Add the machine to a delivery group and launch an ICA session for the machine
- Set the desired audio level for Default Audio Device

- Delete the master image from the delivery group and catalog
- Create an new catalog or upgrade an existing catalog using this Master VM
Problem Cause
HDX audio device is active only in ICA session, hence this setting can be done only in an active ICA session
Was this article helpful?
thumb_up
Yes
thumb_down
No