Service on ADC shows DOWN with monitor error: "No MIP/SNIP available"
book
Article ID: CTX204264
calendar_today
Updated On:
Description
The service on NetScaler shows DOWN with error: "No MIP/SNIP available".
Resolution
To resolve this issue, complete the following steps:
- Make sure that SNIP for the subnet you are trying to connect to is added on the ADC.
- Verify if there exits a route in that Subnet. If the route does not exist then add the route using add route command.
Note:- you might get this error if you have two default routes. Check the show route output and delete one route after confirming from the customer. - Alternatively, you can also create a Net profile with the SNIP that you configired and then Bind it to Service / Service Group to make sure that monitor probes are initiated with that SNIP .
Problem Cause
SNIP is used to communicate with a particular subnet. If the backend server is in the different subnet and there is no route and SNIP on the ADC for communication we can see this error .
Issue/Introduction
The service on ADC shows DOWN with error: "No MIP/SNIP available".
Was this article helpful?
thumb_up
Yes
thumb_down